TM 3-4230-209-20&P
2-152
2-32. LIQUID FUEL WATER HEATER (CONT).
REMARKS
ACTION
LOCATION/lTEM
I
DISASSEMBLY (CONT)
Liquid Fuel Water Heater/
CAUTION
Fitting connector (89)
Do not kink, bend or damage the capillary tube connected
to the indicator thermometer. Any damage will require
replacement.
Loosen fitting connector (89) supplied with the indicator
thermometer located on the control panel and unscrew out
of top of tank unit.
CAUTION
Carefully coil both capillary tubes into a coil no less than six
inches in diameter. Secure to control box.