SERVICE UPON RECEIPT OF MATERIEL. - Continued
SERVICE UPON RECEIPT OF MATERIEL. - Continued

Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  22    23    24    25    26  27  28    29    30    31    32  
img
SERVICE UPON RECEIPT (CONT)
REMARKS
ACTION
LOCATION/lTEM
Pump Unit/
Inspect tachometer cable (8), fuel hose (9), and hose reel pillar
Tachometer cable (8)
blocks (10) to make sure they have not shaken loose.
Fuel hose (9)
Hose reel pillar blocks (10)
Check that three engine shock mount pads (11) have been installed.
Shock mount pads (11)
If not, notify intermediate direct support maintenance personnel.
2-5