TM 10-4330-230-12&P
415. Valves.
This task covers:
Repair
INITIAL SETUP
Tools
Materials/Parts
General Mechanics Tool Kit (Item 1, Appendix B)
Sealing Compound (Item 5, Appendix B)
NOTE
Some models of the fitter/separator are equipped with gate valves. The procedures to
replace and test the valves are the same for all types.
Repair.
(1) Inlet valve. (figure 4-6)
(a) Remove quick disconnect (1) from inlet valve (2).
(b) Remove inlet valve (2) from tank (3).
(c) Apply sealing compound to all pipe threads.
(d) Install inlet valve (2).
(e) Install quick disconnect (1).
(2) Outlet valve. (figure 4-7)
(a)
(b)
(c)
(d)
(e)
Remove quick disconnect (1) from outlet valve (2).
Remove outlet valve (2) from tank (3).
Apply sealing compound to all pipe threads.
Install outlet valve (2).
Install quick disconnect (1).
4-13